< 1 mAPTC terminal current
< 50 ohm ±10%Short-circuit detec-
tion
The PTC input is reinforced/double insulated. If the motor part of the PTC sensor and wiring
are reinforced/double insulated, voltages on the PTC wiring are within SELV limits.
If the motor PTC circuit is not reinforced/double insulated (ie, it is basic insulated), it is
mandatory to use reinforced/double insulated wiring between the motor PTC and CMOD-
02 PTC terminal.
Relay output (62…63)
1.5 mm
2
Maximum wire size
250 V AC / 30 V DC / 5 AMaximum contact
rating
1000 VAMaximum breaking
capacity
External power supply (40…41)
1.5 mm
2
Maximum wire size
24 V AC / V DC ±10% (GND, user potential)Input voltage
25 W, 1.04 A at 24 V DCMaximum power con-
sumption
Isolation areas
CMOD-02
PTC
in
RO PTC24 V
in
1
Plugged to drive SLOT21
Reinforced insulation (IEC 61800-5-1:2007)
Functional insulation (IEC 61800-5-1:2007)
Dimension drawing
The dimensions are in millimeters and [inches].
CMOD-02 multifunction extension module (external 24 V AC/DC and isolated PTC
interface) 281