Type designation key
The type designation contains information on the specifications and configuration
of the drive. The first digits from left express the basic drive type. The optional
selections are given thereafter, separated by plus signs. The main selections are
described below. Not all selections are available for all types. For more information,
refer to the ordering instructions available separately on request.
■
Basic code
DescriptionCode
Product seriesACH580
Type
The standard delivery includes: Wall mounted, IP21 (UL Type 1), ACH-AP-H control
panel with a USB port, integrated EMC filter (C2 in all frames), internal common
mode filter (to be installed by the customer for frame R8), Safe torque off function,
coated boards, cable entry from bottom, multilingual quick installation and start-
up guide (EN + DE, ES, FR, IT, TR).
31
Refer to Option codes (page 41) for options.
Size
See the technical data.xxxx
Voltage range
380…480 V.4
■
Option codes
DescriptionCode
IP55 (UL Type 12)B056
Flange mountingC135
No control panel0J400
Blank control panel cover (no control panel)J424
ACH-AP-H control panel with Bluetooth interfaceJ429
FDNA-01 DeviceNet™ adapter moduleK451
FLON-01 LonWorks
®
adapter moduleK452
FPBA-01 PROFIBUS DP adapter moduleK454
FCAN-01 CANopen adapter moduleK457
FSCA-01 RS-485 (Modbus/RTU) adapter moduleK458
FCNA-01 ControlNet™ adapter moduleK462
Operation principle 41