222 Parameters
42.07 Reopen delay Defines a reopen delay, i.e. the time between when the close
command is given and when the brake can be reopened.
0.00 … 10.00 s Brake reopen delay. 100 = 1 s
42.08 Brake open torq Defines the motor starting torque at brake release (in percent
of the motor nominal torque) when parameter 42.09 Open
torq src is set to P.4 2. 0 8.
Note: If different from 0, this value overrides the setting of
parameter 42.09 Open torq src.
-1000.0 … 1000.0% Motor starting torque at brake release. 10 = 1%
42.09 Open torq src Selects the source for the “brake open” torque value (motor
starting torque at brake release).
See also parameter 42.08 Brake open torq.
Zero Zero speed reference. 0
AI1 scaled 02.05 AI1 scaled (see page 105). 1073742341
AI2 scaled 02.07 AI2 scaled (see page 105). 1073742343
FBA ref1 02.26 FBA main ref1 (see page 109). 1073742362
FBA ref2 02.27 FBA main ref2 (see page 109). 1073742363
D2D ref1 02.32 D2D ref1 (see page 110). 1073742368
D2D ref2 02.33 D2D ref2 (see page 110). 1073742369
Brk torq mem 03.15 Brake torq mem (see page 115). 1073742607
P.42.08 Parameter 42.08 Brake open torq. 1073752584
Pointer Value pointer setting (see Terms and abbreviations on page
102).
-
42.10 Brake close req Selects the source for the brake close/open request.
1 = Brake close request
0 = Brake open request
Note: This parameter cannot be changed while the drive is
running.
DI4 Digital input DI4 (as indicated by 02.01 DI status, bit 3). 1073938945
DI5 Digital input DI5 (as indicated by 02.01 DI status, bit 4). 1074004481
DI6 Digital input DI6 (as indicated by 02.01 DI status, bit 5). 1074070017
DIO4 Digital input/output DIO4 (as indicated by 02.03 DIO status,
bit 3).
1073938947
DIO5 Digital input/output DIO5 (as indicated by 02.03 DIO status,
bit 4).
1074004483
DIO6 Digital input/output DIO6 (as indicated by 02.03 DIO status,
bit 5).
1074070019
Const Bit pointer setting (see Terms and abbreviations on page
102).
-
Pointer
42.11 Brake hold open Selects the source for the activation of the brake open
command hold.
1 = Hold active
0 = Normal operation
Note: This parameter cannot be changed while the drive is
running.
DI4 Digital input DI4 (as indicated by 02.01 DI status, bit 3). 1073938945
DI5 Digital input DI5 (as indicated by 02.01 DI status, bit 4). 1074004481
No. Name/Value Description FbEq