Layout of the input and motor cable connection terminals (frames R10
and R11)
Strain relief1
W2V2U2
L1 L2 L3
1
2
Input power cable terminalsL1, L2, L3
Motor cable terminalsU2, V2, W2
PE terminal2
Layout of the input and motor cable connection terminals (frames R10
and R11 with option +C129)
Strain relief1
W2
V2
U2
L1 L2
L3
1
2
Input power cable terminalsL1, L2, L3
Motor cable terminalsU2, V2, W2
PE terminal2
Entry of external resistor and DC cables
Run the external brake resistor cables and DC cables into the drive cabinet through the
power cable entries at the base of the drive module cubicle. In frames R6 to R8 the
connection terminals are in the drive module. In frame R9, the connection terminals are
located below the drive module.