Control panel
The ACS-AP-W is the user interface of the drive. It provides the essential controls such as
Start/Stop/Direction/Reset/Reference, and the parameter settings for the inverter control
program.
One control panel can be used to control several drives through a panel link.
The control panel can be removed by pulling it forward by the top edge and reinstalled in
reverse order. For the use of the control panel, see ACx-AP-x assistant control panels users
manual (3AUA0000085685 [English]) and the firmware manual.
Control by PC tools
There is a USB connector on the front of the panel that can be used to connect a PC to the
drive. When a PC is connected to the control panel, the control panel keypad is disabled.
Descriptions of options
Note: All options are not available for all drive types, do not coexist with certain other options,
or may require additional engineering. Check actual availability with ABB.
Degree of protection
Definitions
According to IEC/EN 60529, the degree of protection is indicated by an IP code where the
first numeral means protection against ingress of solid foreign objects, and the second
numeral protection against ingress of water. The IP codes of the standard cabinet and
options covered in this manual are defined below.
The equipment is protected
IP code
Second numeralFirst numeral
against dripping (15° tilting) wateragainst ingress of solid foreign objects > 12.5 mm
diameter *
IP22
against dripping (15° tilting) wateragainst ingress of solid foreign objects > 1 mmIP42
against splashing waterdust-protectedIP54
* meaning for protection of persons: against access to hazardous parts with finger
Operation principle and hardware description 49