Mechanical installation
Contents of this chapter
This chapter describes the mechanical installation procedure of the drive.
Examining the installation site
Examine the installation site. Make sure that:
• The installation site is sufficiently ventilated or cooled to remove heat from the drive. See
the technical data.
• The ambient conditions of the drive meet the specifications. See the technical data.
• There is sufficient free space above the drive for cooling, maintenance, and operation
of the pressure relief (if present).
• The floor that the drive cabinet is installed on is of non-flammable material, as smooth
as possible, and strong enough to support the weight of the unit. Check the floor flatness
with a spirit level. The maximum allowed deviation from the surface level is 5 mm (0.2 in)
in every 3 meters (10 ft). Level the installation site, if necessary, as the cabinet is not
equipped with adjustable feet.
4
Mechanical installation 65