Cabinet layout of frames R10 and R11 top entry and exit of cables
(option +C129)
The cabinet layout is shown below.
1
3
2
BA
4
7
5
6
8
9
10
11
12
B - Drive module cubicleA Main breaker and power cabling cubicle
Drive module8Main fuses for control devises, IP54 fan trans-
former (with option +B055), V-meter (option
+G334), starter for auxiliary motor fan (option
+M600)
1
Control unit9AC fuses2
Optional terminal block for external control unit
connections (X504, option +L504)
10Main switch-disconnector3
Auxiliary voltage transformer (T21)11Input and motor cable connection terminals4
Cabinet heater12PE-terminal5
--Power and control cable entries6
--“Door” fan7