Cooling data and noise for drives with sine filter (option
+E206)
NoiseAir flowHeat dissipationSine filter typeFrameACS880-
07-…
TotalFilterDriveTotalFilterDrive
dBAm
3
/hm
3
/hm
3
/hkWkWkW
U
n
= 400 V
801750*17502.40.61.8B84143V0130S230R60105A-3
801750*17502.50.61.9B84143V0162S229R60145A-3
801750*17503.00.62.4B84143V0162S229R70169A-3
801750*17503.70.92.8B84143V0230S229R70206A-3
801750*17504.70.93.8B84143V0230S229R80246A-3
801750*17506.01.64.4B84143V0390S229R80293A-3
801150*11506.91.65.3B84143V0390S229R90363A-3
801150*11508.11.66.5B84143V0390S229R90430A-3
804950200029509.13.06.1NSIN0900-6R100505A-3
8049502000295011.33.46.9NSIN0900-6R100585A-3
8049502000295012.43.88.6NSIN0900-6R100650A-3
8049502000295013.34.19.2NSIN0900-6R110725A-3
8049502000295015.44.710.4NSIN0900-6R110820A-3
8051702000317016.15.011.1NSIN0900-6R110880A-3
U
n
= 500 V
801750*17502.40.61.8B84143V0130R230R60096A-5
801750*17502.50.61.9B84143V0130R230R60124A-5
801750*17503.00.62.4B84143V0162R229R70156A-5
801750*17503.40.62.8B84143V0162S229R70180A-5
801750*17504.70.93.8B84143V0230S229R80240A-5
801750*17505.30.94.4B84143V0230S229R80260A-5
801150*11506.91.65.3B84143V0390S229R90361A-5
801150*11508.11.66.5B84143V0390S229R90414A-5
80365070029507.23.34.9NSIN0485-6R100460A-5
804950200029509.73.66.1NSIN0900-6R100503A-5
8049502000295010.83.96.9NSIN0900-6R100583A-5
8049502000295012.94.38.6NSIN0900-6R100635A-5
8049502000295014.24.99.3NSIN0900-6R110715A-5
80495020002950165.610.4NSIN0900-6R110820A-5
8049502000295016.75.611.1NSIN0900-6R110880A-5
U
n
= 690 V
781750*17502.10.31.8B84143V0056S230R60061A-7
791750*17502.50.61.9B84143V0092S230R60084A-7
791750*175030.62.4B84143V0092S230R70098A-7
801750*17503.40.62.8B84143V0130S230R70119A-7
801750*17504.40.63.8B84143V0130S230R80142A-7