Transportation
in the protective package
Storage
in the protective package
Operation
installed for stationary
use
Max. 95%Max. 95%Max. 95%Relative humidity
No condensation allowed. Maximum allowed relative humidity is 60% in the presence
of corrosive gases.
IEC 60721-3-2:1997IEC 60721-3-1:1997IEC/EN 60721-3-3:2002:
Classification of environ-
mental conditions - Part 3-
3: Classification of groups
of environmental paramet-
ers and their severities -
Stationary use of weather
protected locations
Contamination
Chemical gases: Class
2C2
Solid particles: Class 2S2
Chemical gases: Class
1C2
Solid particles: Class 1S3
(packing must support this,
otherwise 1S2)
Chemical gases: Class
3C2
Solid particles: Class 3S2
(3S1 with IP20). No con-
ductive dust allowed.
2Pollution degree
IEC/EN 60721-3-2:1997IEC/EN 60721-3-1:1997IEC/EN 60721-3-3:2002Vibration
2…9 Hz: max. 3.5 mm
amplitude
10…57 Hz: max. 0.075 mm
amplitude
10…57 Hz: max. 0.075 mm
amplitude
IEC/EN 61800-5-1
IEC 60068-2-6:2007,
EN 60068-2-6:2008 Envir-
onmental testing Part 2:
Tests –Test Fc: Vibration
(sinusoidal)
9…200 Hz: 10 m/s
2
(32.8 ft/s
2
)
57…150 Hz: 1 g57…150 Hz: 1 g
Units with marine construc-
tion (option +C121): Max.
1 mm (0.04 in)
(5 … 13.2 Hz), max. 0.7 g
(13.2 … 100 Hz) sinusoidal
With packing max.
100 m/s
2
(328 ft/s
2
) 11 ms
With packing max.
100 m/s
2
(328 ft/s
2
) 11 ms
Not allowedShock
IEC 60068-2-27:2008, EN
60068-2-27:2009
Environmental testing -
Part 2-27: Tests - Test Ea
and guidance: Shock
Auxiliary circuit power consumption
100 WCabinet heater and cabin-
et lighting (options +G300
and +G301)
150 WExternal uninterruptible
power supply (option
+G307)
According to the heater typeMotor heater (option
+G313)
Materials
■ Cabinet
Zinc coated steel sheetEnclosure
226 Technical data