Type designation key
The type designation contains information on the specifications and configuration of the
drive. The first digits from left express the basic configuration (eg, ACS880-07-240A-5). The
optional selections are given thereafter, separated by plus signs, eg, +E202. The main
selections are described below. Not all selections are available for all types. For more
information, refer to ACS880-X7 single drives ordering information (3AXD10000052815,
available on request).
■ Basic codes
DescriptionCode
Product seriesACS880
When no options are selected: cabinet-installed drive, IP22 (UL Type 1), main switch-disconnector
(switch fuse with aR fuses), ACS-AP-W assistant control panel with Bluetooth interface, no EMC
filter, built-in input DC choke (frames R6 to R9), built-in input AC choke (frames R10 and R11),
coated boards, ACS880 primary control program, Safe torque off function, bottom entry and exit of
cables, multilingual device label sticker, USB memory containing circuit diagrams and all manuals.
07
Size
See Ratings (page 197).
xxxx
Voltage range
380…415 V. This is indicated in the type designation label as typical input voltage level 3 ~ 400 V AC.3
380…500 V. This is indicated in the type designation label as typical input voltage levels 3 ~
400/480/500 V AC.
5
525…690 V. This is indicated in the type designation label as typical input voltage levels 3 ~
525/600/690 V AC.
7
■ Option codes
DescriptionCode
IP42 (UL Type 1 Filtered)B054
IP54 (UL Type 12)B055
Marine construction. See section Marine construction (option +C121) (page 50).
C121
Air inlet through bottom of cabinet. See section Air inlet through the bottom of cabinet (option
+C128) (page 82).
C128
UL Listed (evaluated to both U.S. and Canadian safety requirements). See section UL Listed (option
+C129) (page 50).
C129
Channeled air outlet. See section Channeled air outlet (option +C130) (page 50).
C130
Marine type approval. Refer to ACS880 +C132 marine type-approved cabinet-built drives supplement
(3AXD50000039629 [English]).
C132
CSA approved. See section CSA Approved (option +C134) (page 51).
C134
Plinth height 100 mm. See section Plinth height (options +C164 and +C179) (page 51).
C164
Plinth height 200 mm. See section Plinth height (options +C164 and +C179) (page 51).
C179
Seismic design. See section Seismic design (option +C180) (page 51).
C180
Empty 400 mm wide cubicle on right. See section Empty cubicles on right (options
+C196…C198) (page 51).
C196
Empty 600 mm wide cubicle on right. See section Empty cubicles on right (options
+C196…C198) (page 51).
C197