Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
100.00 rpm / real32Defines the “at setpoint” limits for speed control of the
drive.
When the absolute difference between reference (22.87
Speed reference act 7) and actual speed (90.1 Motor
speed for control) becomes smaller than half the value
of 46.21 At speed hysteresis, the drive is considered to
be “at setpoint”.
This is indicated by bit 8 of 6.11 Main status word.
The bit switches off when the absolute difference
between reference and actual speed exceeds the value
of 46.21 At speed hysteresis.
Hysteresis
Drive at setpoint
(
06.11
bit 8 = 1)
Hysteresis
22.87
+
46.21
(rpm)
22.87
+ 0.5 x
46.21
(rpm)
22.87
(rpm)
22.87
- 0.5 x
46.21
(rpm)
22.87
-
46.21
(rpm)
0 (rpm)
90.01
(rpm)
At speed hysteresis46.21
- / -Limit for “at setpoint” indication in speed control. For
scaling, see parameter 46.1.
0.00 ... 30000.00
rpm