3.6 Setting the Configuration Chapter 3: Configuration
70 493-0736-11 (6-2)
Figure 38 The relationship between Displayed Value and Signal Range.
The Signal Range is the range of the signal available on the output of the block.
This range is
MinValue Va l u e MaxValue
The default values of MinValue (0.0%) and MaxValue (100.0%) define the default
(signal) range
–100.0% Value 100%
By adjusting MinValue and MaxValue, the user can limit the (signal) range to
positive values only (MinValue = 0.0%) or any other permissible range.
The Displayed Range is the range of the value presented on the display. This range
is
LoLimit Displayed Value HiLimit
MaxValue
MinValue
Displayed Value
Signal Range
LoLimit HiLimit