3 Maintenance
3.6.1. Cleaning of Robot Standard and Wash Down
1073HAC030005-001 Revision: -
© Copyright 2006 ABB. All rights reserved.
Usable Detergents
The stainless version is verified against the following detergents.
2. Foam with “P3-Topax 12” with a
concentration of approximately
3% depending on the type of
dirt. The water temperature
should be 40-60°C. The solvent
should be applied to the whole
external surface.
3. Wait about 15 minutes so the
solvent takes effect.To retain
effective cleaning properties,
ensure that the solvent does not
dry on the surface.
4. Flush thoroughly with water.
5. Apply the disinfectant, we
recommend “P3-Topax 99”.
Time, concentration, and water
temperature are chosen to
reach the desired effect.
• Concentration = 1-2%
• Temperature = 10-40°C
• Time approx. 20 min.
6. Flush thoroughly with water.
Sealings should be lubricated
after cleaning, for good function-
ality.
7. After cleaning bearing races
and “swivel cup” sealing,
lubricate them with provision
classified grease.
8. Due to the risk of damaging the
ball bearing, do not clean with
any detergent when the swivel
cup is removed, only use a
moistened cloth.
9. If the Labels on the robot are
damage in the cleaning
procedure, apply new labels.
Described in section Replacement of labels on page
153
Action Note
Strongly alkaline: Topmaxx 421 (3%)
Strongly alkaline with chloride: P3-topax M55 (3%)
Strongly acid (for removing calcium oxide): P3-topax 56 (3%)
Acid (for disinfection): P3-topactive DES (1%)
Continued
Continues on next page