4 Repair
4.3.7. Replacement of Telescopic Shaft
3HAC030005-001 Revision: -134
© Copyright 2006 ABB. All rights reserved.
Removal
Refitting
Replacement of Movable Plate on page 130
References
Action Note
1. Remove the Parallel
Arms
Described in section Replacement of Parallel Arms on page
120
2. Remove the Movable
Plate
Described in section Replacement of Movable Plate on page
130
3. Remove the upper Set
screw.
xx0700000612
TIP!
Use a 90° angled bit holder.
4. Remove the Telescopic
Shaft.
Action Note
1. Refit the Telescopic
Shaft.
Continued
Continues on next page