EasyManua.ls Logo

ABB IRB 360/3 - Page 188

ABB IRB 360/3
248 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Calibration information
5.9. Serial Measurement Board memory
3HAC030005-001 Revision: -186
© Copyright 2006 ABB. All rights reserved.
Delete SMB data
This section describes how to delete the data stored on the SMB memory or the controller
memory, when creating spare parts.
Related information
Operating manual - RobotStudio Online.
Operating manual - Service Information System.
Application manual - Motion performance.
Action
1. On the ABB menu, tap Calibration and tap to select a mechanical unit.
2. Tap SMB memory and then tap Advanced.
The following functions are available:
Clear Cabinet Memory
Clear SMB Memory
3. Tap Clear Cabinet Memory if the controller should be replaced and used as a spare
part.
A list of the SMB data stored in the controller is displayed. Tap Clear to delete the
memory for the selected robot. Repeat the procedure for all robots in the controller
memory.
4. Tap Clear SMB Memory if the SMB should be replaced and used as a spare part.
A list of the SMB data stored is displayed. Tap Clear to delete the memory for the
selected robot. Repeat the procedure for all robots using this SMB board.
Continued

Table of Contents

Related product manuals