NoteAction
The figure shows Other design than Type
C. The principle of securing the bracket
on Type C is the same.
xx0900000018
Secure the bracket on its attachment screws
in the base.
Tip
Perform this in the following order:
Put the attachment screws in the
holes but do not tighten them yet (if
they have been removed earlier).
Place the bracket on the attachment
screws.
Secure the bracket with its attach-
ment screws.
4
Parts:
A: Base
B: Attachment screws (2 pcs)
C: Bracket
xx0900000015
Refit the earth cables.5
Parts:
A: Earth
B: Distance screws
Connect the contacts on the SMB unit:
R1.SMB1-2
R1.SMB3-6
R2.SMB
6
How to refit the SMB unit is described in
section:
Refitting the SMB unit on page 226
Refit the SMB unit.7
Continues on next page
3HAC033453-001 Revision: H 215
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.3.2 Refitting the complete cable harness
Continued

Table of Contents