NoteAction
A
xx0900000035
Refit the cables with the screen connec-
tions.
8
Parts:
A: Screen connections (4 pcs)
xx0900000013
Tip
When refitting connectors on the bracket,
put it at a 90° angle.
9
Parts:
A: Bracket
B: Base
A
B
C
xx1200000857
A R1.CP/CS
B R1.MP
C Air hose
Before refitting the connectors on the
bracket, arrange cables and connectors as
shown in the figure.
10
Continues on next page
216 3HAC033453-001 Revision: H
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.3.2 Refitting the complete cable harness
Continued