Removing the main harness from the cable arm position
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
For rear outlet cable version:Pull the main harness out of the outer arm from
lower of the cable arm.
Tip
Wrap the connectors with the masking tape.
2
xx2300000507
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
For underneath outlet cable ver-
sion:
xx2300000612
Pull the main harness out of the cable arm from
the inner arm.
3