Note/IllustrationAction
For the connected services gateway:
• K7.X1 - K2.X3
i
• K7.X2 - A2.X5
Note
The connector K7.X2 is locked;
grab the connector, push it in to
release it and then remove the
connector.
For the main computer:
• A2.X1 - K2.X2
• A2.X3 - X24
• A2.X4 - K4.X6/K5.1.X5
Note
If the Ethernet extension switch is
installed, connect and disconnect
the connector A2.X4 to/from
K4.X6.
If the Ethernet extension switch is
not installed, connect and discon-
nect the connector A2.X4 to/from
K5.1.X5.
• A2.X5 - K7.X2
• A2.X6 - K2.X8
• A2.X9 - A1.X3
• A2.K3.X1 - K2.X3
• A2.K3.X6, A2.K3.X7 - K2.X12
i
For Connected Services Gateway wired, there is no power cable.
Removing the robot signal exchange proxy
Note/IllustrationAction
xx1900001886
Pull the cable ties out from the locking
holes.
1
Continues on next page
Product manual - OmniCore V250XT 237
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.8 Replacing the main computer
Continued