Note/IllustrationAction
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx2100000318
Removing the power supply
Note/IllustrationAction
xx1900001907
Remove the end clamp besides the
power supply with a screwdriver.
1
xx1900001908
Disconnect:
T5.X1-A1.X7Terminal block
T8.X1-A1.X15Terminal block
T5.X2-24VTerminal block
T8.X2-24VTerminal block
2
Remove the screw and the power supply.3