5 Click Apply.
The camera’s internal settings are now modified. If the calibration is
successful the color image and the grayscale image of the white paper sheet
should now look the same (gray).
6 Right-click the camera and select Save.
The settings are stored in the camera. If the parameters are not saved, the
camera will loose the calibration when PickMaster PowerPac is restarted.
Illustration Color Filter Settings
xx1900000943
Configuring color vision
The PatMax and Blob configuration dialogs contain a checkbox to enable color
filtering (Color filter), and a button to display the filter settings (Set).
Use this procedure to configure color vision.
1 In the Image part of the PatMax or Blob configuration dialog, select Color
Filter. This will enable the filter.
xx1900000941
The Color Filter Settings dialog is opened together with a second video
window showing the color image.
2 In the Color Filter part, select RGB or HSI.
Continues on next page
292 Application manual - PickMaster® Twin - PowerPac
3HAC064218-001 Revision: B
© Copyright 2021 ABB. All rights reserved.
4 Working with PickMaster PowerPac
4.4 Using color vision
Continued

Table of Contents