1.4.3 Functions, codes and symbols
All available functions are listed in the table. All of them may not be applicable to all
products.
Table 1: Functions included in the relays
Function IEC 61850 IEC 60617 IEC-ANSI
Protection
Three-phase non-directional overcurrent protection, low stage, in-
stance 1
PHLPTOC1 3I> (1) 51P-1 (1)
FPHLPTOC1 F3I> (1) F51P-1 (1)
Three-phase non-directional overcurrent protection, high stage,
instance 1
PHHPTOC1 3I>> (1) 51P-2 (1)
Three-phase non-directional overcurrent protection, instantane-
ous stage, instance 1
PHIPTOC1 3I>>> (1) 50P/51P (1)
Three-phase non-directional overcurrent protection, instantane-
ous stage, instance 2
PHIPTOC2 3I>>> (2) 50P/51P (2)
Three-phase directional overcurrent protection, low stage, in-
stance 1
DPHLPDOC1 3I> -> (1) 67-1 (1)
FDPHLPDOC1 F3I> -> (1) F67-1 (1)
Three-phase directional overcurrent protection, low stage, in-
stance 2
DPHLPDOC2 3I> -> (2) 67-1 (2)
FDPHLPDOC2 F3I> -> (2) F67-1 (2)
Three-phase directional overcurrent protection, low stage, in-
stance 3
DPHLPDOC3 3I> -> (3) 67-1 (3)
Three-phase directional overcurrent protection, low stage, in-
stance 4
DPHLPDOC4 3I> -> (4) 67-1 (4)
Three-phase directional overcurrent protection, high stage, in-
stance 1
DPHHPDOC1 3I>> -> (1) 67-2 (1)
Three-phase directional overcurrent protection, high stage, in-
stance 2
DPHHPDOC2 3I>> -> (2) 67-2 (2)
Three-phase directional overcurrent protection, high stage, in-
stance 3
DPHHPDOC3 3I>> -> (3) 67-2 (3)
Three-phase directional overcurrent protection, high stage, in-
stance 4
DPHHPDOC4 3I>> -> (4) 67-2 (4)
Non-directional earth-fault protection, low stage, instance 1 EFLPTOC1 Io> (1) 51N-1 (1)
FEFLPTOC1 FIo> (1) F51N-1 (1)
Non-directional earth-fault protection, high stage, instance 1 EFHPTOC1 Io>> (1) 51N-2 (1)
Non-directional earth-fault protection, instantaneous stage, in-
stance 1
EFIPTOC1 Io>>> (1) 50N/51N (1)
Directional earth-fault protection, low stage, instance 1 DEFLPDEF1 Io> -> (1) 67N-1 (1)
FDEFLPDEF1 FIo> -> (1) F67N-1 (1)
Directional earth-fault protection, low stage, instance 2 DEFLPDEF2 Io> -> (2) 67N-1 (2)
FDEFLPDEF2 FIo> -> (2) F67N-1 (2)
Directional earth-fault protection, low stage, instance 3 DEFLPDEF3 Io> -> (3) 67N-1 (3)
Directional earth-fault protection, low stage, instance 4 DEFLPDEF4 Io> -> (4) 67N-1 (4)
Table continues on the next page
Introduction 1MRS758755 C
22 REC615 & RER615
Technical Manual