-EN Rev. E Operating instruction SCK Gas Sampling System 133
After first insertion, check the direction of rotation of the rotor on the heat
exchanger:
Step
Procedure
1
The rotor must turn clockwise. If necessary, adjust the direc-
tion of rotation by changing the phase.
Owing to the greater flow speeds in this process, after start-up the gas sam-
pling probe must be checked frequently for wear at the calcinator gas outlet
measuring point. If distinct signs of wear are visible after a short time, check
the installation position of the gas sampling probe. Failing to observe this can
lead to severe damage or total loss of the gas sampling probe.