78 Operating instruction SCK Gas Sampling System OI/SCK-EN Rev. E
Danger Where / in what situa-
tion does the danger
Preventive action
Risk of burning due
to falling or spall-
ing material.
After the probe moves
out of the rotary kiln,
hot material may fall or
spall off the probe.
Never enter the danger
area around the retractor
during operation.
Do not approach the
retracted probe until it
has cooled down.
If it is unavoidable to
approach the hot probe,
wear a face mask against
heat, heat-proof gloves
and protective welder's
clothing.
Danger due to
harmful gases, jet
flames
If gases escape from
the duct opening on
the rotary kiln when
the shutter is open
Never enter the danger
area around the retractor
during operation.
Ensure adequate ventila-
cooling water
cooling water escaping
if an error occurs
Wait until the entire cool-
ing water has been evac-
uated before approach-
harmful anti-freeze
ing from the cooling
system in the event of
an error
cooling water and the an-
ti-freeze.
Wash any cooling water
or anti-freeze off the skin
immediately with water
and soap.
If cooling water or anti-
freeze gets in the eyes
despite protective glass-
es, rinse them thoroughly
under running water,
holding the eyelids open.
Observe instructions in
the anti-freeze manufac-
turer's safety data sheet.
harmful lubricating
oil
ing from the pneumat-
ic module in the event
of an error
Avoid contact with lubri-
cating oil.
Wash any lubricating oil
off the skin immediately
with water and soap.
If any lubricating oil gets
in the eyes despite pro-
tective glasses, rinse
them thoroughly under
running water, holding
the eyelids open.
Observe instructions in
the lubricating oil manu-
facturer's safety data