MC97F6108A User’s manual 18. Reset
195
18.5 Brown out detector processor
MC97F6108A has an On-chip brown-out detection circuit (BOD) for monitoring VDD level during
operation by comparing it to a fixed trigger level. Trigger level for the BOD can be selected by
configuring BODLS[2:0] bits to be 2.2V, 2.5V, 2.7V, 3.2V, 3.7V, 4.2V.
In the STOP mode, this will contribute significantly to the total current consumption. So to minimize the
current consumption, select BODLS[2:0] to 000b to disable BOD by software.
Figure 95. BOD Block Diagram
Figure 96. Internal Reset at Power Fail Situation