Abov MC97F6108A - Figure 58. PPG Off-Time MaxMin Limitation

Default Icon
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC97F6108A User’s manual 11. PPG (Programmable Pulse Generator)
115
PPGO
C0_FLAG
CPOUT0
PERIO D
OFFMINHR/OFFMINLR
30
OFFMAXHR/OFFMAXLR
50
PPG off-time counter
PERIOD
10 029...
30
49... 500
PPG off-time min detect
PPG off-time max match
... ... 3029
...
0381
PERIO D
... 3029
...
1
MIN detect
MAX detect
Figure 58. PPG Off-time Max/Min Limitation