EasyManuals Logo

Abov MC97F6108A User Manual

Default Icon
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
MC97F6108A User’s manual 11. PPG (Programmable Pulse Generator)
105
11.8.2 PPG period when ATPSEL = 2'b00
When comparator 2 outputs low and ATPSEL is 2'b00, ATPHR/ATPLR (the period register in auto
period mode) is maintained as the current period.
{PPGH, PPGL}
(16-bit Counter)
ATPRL
(8-bit)
0 1
MUX
- DSTEP[7:0]
00 01 10 11
MUX
CPOUT2
(in the previous period)
current period
+ USTEP[7:0]
increase
decrease
ATPSEL[1:0]
ATPEN
0 1
MUX
PPGPL
(8-bit)
PPG start
read only
PPG period register
PERIOD write
M 0
U
X 1
M 0
U
X 1
ATPMAXHR
(8-bit)
ATP_MAX
ATPEN
~(PERIOD write)
MAX match
MIN match
current period
current period
ATPEN
PPGPH
(8-bit)
ATPMAXHR
(8-bit)
ATPMINHR
(8-bit)
ATPMINHR
(8-bit)
ATPRH
(8-bit)
period matching
CMP2
C2DBSEL[1:0
]
by pass
0.3 us
0.6 us
1.2 us
ATP_MIN
Figure 45. Auto Period Mode Block Diagram (ATPSEL = 2'b00)
PPGO
ATPHR, ATPLR
start pulse
1
A
CPOUT2
DSTEP
9
PPGPH/PPGPL
A
8 7
PERIO D=A PERIOD=9 PERIOD=9 PERIO D=9 PERIO D=8 PERIOD=8 PERIOD=7
< ATPSEL = 2'b00 >
ATPEN
Figure 46. Auto Period Mode (ATPSEL = 2'b00)