11. PPG (Programmable Pulse Generator) MC97F6108A User’s manual
100
11.5 Disable PPG output by comparator 1
PPGH/L (16-bit Counter)
DUTY Compare
REGISTER
Clear & Start
PERIOD Compare
REGISTER
S
R
Q
clear
PPG_PE
PPGO
DETC1EN
PPG_CLK
PPG
-
+
CMP1
by pass
0.3 us
0.6 us
1.2 us
C1DBSEL[1:0]
CFEDGE[1]
CFPOLA[1]
CFBOTH[1]
CFENAB[1]
C1_FLAG
Figure 37. Disable PPG Output by Comparator 1
PPG output is disabled by comparator 1 flag (C1_FLAG) with enable bit DETC1EN in the PPGCR2
register. When DETC1EN is set and comparator 1 output occurs, PPG outputs it's default value.
C1_FLAG is cleared by writing '0'. Once PPG output is disabled by C1_FLAG, C0_FLAG is not
generated until C1_FLAG is cleared.
C1_FLAG
DUTY
C0_FLAG
PPGO
PERIOD
DUTY
PERIOD
PPGO_PRE
Write 0
PPGST
PPGMD
software start
PERIOD
PPGIF TPPGOen PPGMD DETC3EN
DETC1EN
- - -
PPGCR2
ADDRESS :
E1
H
Figure 38. Disable PPG Output by Comparator 1 (C1_FLAG)