EasyManua.ls Logo

Abov MC97F6108A - Brown out Detector Characteristics; Power on Reset Characteristics; Table 45. Brown out Detector Characteristics; Table 46. Power-On Reset Characteristics

Default Icon
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC97F6108A User’s manual 20. Electrical characteristics
223
20.8 Brown out Detector characteristics
Table 45. Brown out Detector Characteristics
(T
A
=-40°C ~ +85°C, VDD=2.7V ~ 5.5V, VSS=0V)
Parameter
Symbol
Conditions
MIN
TYP
MAX
Unit
Detection level
BOD6
3.8
4.2
4.6
V
BOD5
3.3
3.7
4.1
BOD4
2.8
3.2
3.6
BOD3
2.3
2.7
3.1
BOD2
2.1
2.5
2.9
BOD1
1.8
2.2
2.6
Hysteresis
△V
50
mV
Operating current
I
BOD
50
uA
NOTE: Guaranteed by design.
20.9 Power on Reset characteristics
Table 46. Power-on Reset Characteristics
(T
A
=-40°C ~ +85°C, VDD=2.7V ~ 5.5V, VSS=0V)
Parameter
Symbol
Conditions
MIN
TYP
MAX
Unit
RESET release level
V
POR
1.2
1.4
1.6
V
POR current
I
POR
0.1
uA
VDD voltage rising rate
V
RR
0.05
5.0
V/ms
Minimum pulse width
t
LW
100
us