EasyManua.ls Logo

Adtech ADT-DK300A - Page 114

Adtech ADT-DK300A
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BZ001M056A ADTDK300A/400A Engraving Machine
105
Range :‐9999~9999
Unit : mm
Authority : Operationadminorhigher
Default : 0.000
Effectivetime : Instant
Note : The offset range when the screwoffset function is turned on. The set
position is the machine coordinates. For example, if the coordinate
rangeofthemachineis0~100mm,you
cansetthestartingpositionto0,
and set the end position to100.The coordinates in thisrange arenot
compensated.
128 GotoM98time/lineenable
Range : ON&OFF
Unit : None
Authority : Operationadminorhigher
Default : OFF
Effectivetime : Instant
Note : Inthestructurethatthemainprogramrepeatedlycallssubroutines,the
usercanturnonthisparameterandruntheprogramdirectly.SelectON,
press'',andenterthe
callingtimeandlinetorundirectly.
129 Systemstartreset
Range : Never,Ask,Always
Unit : None
Authority : Operationadminorhigher
Default : Never
Effectivetime : Instant
Note : Settheresetmodeafterthe systemisstarted. Neverindicates that do
notresetafterstarted;askindicatesthatthesystemaskswhetherreset
afterstarted(pressEOBto
resetorpressCanceltoexit);alwaysindicates
thatthesystemresetsautomaticallyafterstarted.
130 Cooleralarmeffectivelevel
Range : 0&1
Unit :
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note :
Purposeandfunctiontobespecified
131 Externalreseteffectivelevel
Range : 1&0
Unit :