BZ001M056A ADTDK300A/400A Engraving Machine
142
11.1.3. Installationprecautions
Installationconditionforelectriccabinet
(1)Thecabinetmustbeabletoeffectivelypreventdust,coolantandorganicsolutionentering;
(2) When designelectric cabinet,the distancebetween rear cover and case should be at least 20CM;
consideringthetemperaturerisesinthecabinet,thetemperaturedifferencebetweeninteriorandexteriorof
thecabinetshouldn’texceed10;
(3)Thecabinetshouldbeinstalledwithfantoensureinteriorventilation;
(4)Thedisplaypanelshouldbeinstalledatthepositioncan’tbesprayedbythecoolant;
(5) When design electric cabinet, the external electrical interference should be reduced to lowest to
preventinterferingwiththesystem;
Topreventinterference
The system is designed with antiinterference measures such as shielding space electromagnetic
radiation, absorbing impact current and filtering power clutter, which can prevent interference with the
systemincertaindegree.Toensuresystemstability,pleasetakethefollowingmeasurestoinstalland
connect