BZ001M056A ADT‐DK300A/400A Engraving Machine
61
(5)Press ,thesystemaskswhetherclearallparameters,asshowninFig.9‐3;press[EOB]again,
thesystemrestoresthedefaultparametersandrestartsautomatically.
Fig.9‐3
9.4. Parameterbackupandrestore
This function can back up the modified parameters. When the system is updated or initialized, the
parameters can be restored to avoid setting the parameters repeatedly. The backup files can be copied to
otherengravingsystem.Therefore,pleasebackuptheparametersafteradjustingandrestoretheparameters
directlyinthe
newmachine.Theparameterbackupandrestoremethodisdescribedbelow:
(1)Selecttheeditmode;
(2)Inthemainmenu,press[Parameter]toentertheparameterinterface;
(3)Pressthe[Management]keytoenterthemanagementparameterinterface;
(4)Movecursorto007or008,andselectcorrespondingoperation
menu;
(5)Press[EOB],thesystemconfirms,andperformsbackuporrestoreoperation;
(6)ThebackupoperationwillgeneratetheSYSCONF.BAKfileintherootdirectoryofdiskD.Pleasesave
thisfileforbackupinthefuture.