BZ001M056A ADT‐DK300A/400A Engraving Machine
130
Default : 0
Effectivetime : Instant
Note : Theseparametersarereservedforthesystem.
030 Systemspindlespeed
Range : 1~24000
Unit : None
Authority : Operationadminorhigher
Default : 100
Effectivetime : Instant
Note : Setspindle speed S value of the system.If the user programusesone
spindle for speed processing, set the desired spindle speed, and the
spindlecodedoesn’tneedto
bewrittenintheprogram.Iftheprogram
hasspind le code,thesystem willperformthe programming speedand
saveinparameters.
031 IfclosespindlewhileexecutingM30
Range : 0~1
Unit : None
Authority : Operationadminorhigher
Default : 1
Effectivetime : Instant
Note : This par ameter sets whether to automatically open and close the
spindlewhentheprogramautomaticallystartsandends.Ifsetto1,the
spindle automatically closes before started, and automatically
stops
duringoperation;afterstarted,thespindleautomaticallyopens.
10.7. Portconfiguration(P6.)
001
Wheel0.1‐‐‐‐‐‐‐‐InputwireNo.
…
…
014
AAlarm‐‐‐‐‐‐InputwireNo.
Range : 24~37
Unit : None
Authority : SuperAdmin
Default : Theporttableinthemanual
Effectivetime : Instant
Note :
Handheldboxinterfaceandservoalarmfunctionpindefinition;
Servo alarm input port, handheld box position, axis selection, start,
pause, and emergency stop input port can be
configured. The default
handheld box testing port is XS7, and servo alarm detection port is
XS1~XS4.