BZ001M056A ADT‐DK300A/400A Engraving Machine
129
therotationdirectlylater,whilethecontrollerwilloutputcorresponding
analogvoltageaccordingtolinearscaleautomatically.
022
Spi.GearNumerator
023
Spi.GearDenominator
Range : 1~65535
Unit : None
Authority : Operationadminorhigher
Default : 1
Effectivetime : Instant
Note : Iftheprincipalaxishasgearposition,pleasesetthehardwaregearratio
tothisparameter,whichhasn’tbeenusedinstandardversion,butmay
beusedincertainspecial
conditions.
024 Spi.EncoderLogicDir
Range : 0~1
Unit : None
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note : Thedirectionofrotationofthespindleencoder.
025 Spi.OpenDelayTime(ms)
Range : 0~9000
Unit : Ms
Authority : Operationadminorhigher
Default : 6000
Effectivetime : Instant
Note : Set the delay time through this parameter to start the spindle. The
parameterismainlytopreventprocessingbeforethespindleisstarted.
026
Servospindlereadylevel
027
Servospindlequasistopin‐placelevel
028
Servospindlezerospeedin‐placelevel
029
Servospindlespeedarrivallevel
Range : 0~1
Unit : None
Authority : Operationadminorhigher