BZ001M056A ADT‐DK300A/400A Engraving Machine
128
017
Spi.MaxAcc(Kpps)
018
Spi.ExtHomeDir
019
Spi.ServoHomeDir
021
Spi.HomeSpeed(rpm)
Range : 0~1
Unit : Logiclevel
Authority : Operationadminorhigher
Default : 0
Effectivetime : Instant
Note : Servo principal axis parameters are same as common positioning axis
parameters. If only the principal axisiscontrolled with servoport, you
cansetthenumberaccordingtoaxis
parameters.
013 Spi.Encodebits(p)
Range : 64~9999
Unit : None
Authority : Operationadminorhigher
Default : 2500
Effectivetime : Instant
Note : Thereceivedwirenumberoftheencoderwhentheprincipalaxisrotates
onecircle;
Sameascommonaxisencoder,itcanonlyreceiveABphasepulse,and
thus the wire number of the encoder must be pulses of one circle
dividedby4.
This parameter will affect G74 and G84 tap instructions. Please set it
properly.
020 Spi.MaxSpeed(rpm)
Range : 1~30000
Unit : None
Authority : Operationadminorhigher
Default : 24000
Effectivetime : Instant
Note : Thissettingisusedtocalculatetheanalogoutputofthecontroller,and
supposethattheanalogofvariablefrequencycontrolisinlinearcontrol
mode;
This method is to set the rotation to this parameter according to the
variable frequency rotation corresponding to analog 10V, and transfer