5.2 Hardlimitovertravel
Thesystemalarmsifthetooltouchestravelswitchduringoperation.Theaxisincorrespondingdirection
can’t move, and only moves in reverse direction. Before the alarm is released, the system can’t enter
automatic operation normally. After investigating the alarm reason, press [
] to clear the alarm
information.
5.3 Softlimitovertravel
Ifthe toolenterstherestrictionarearegulatedby theparameter(travellimit),thesystemalarmsover
travel,andthetooldeceleratesandstops.Atthismoment,youcanmovethetooltosafedirectioninmanual
mode,andthenpress[
]toreleasethealarm.
0 Caution:
Duringautomaticoperation,whenthetooltouchesanaxialtravelswitch,thetooldeceleratesandstopsallaxialmotions,
andonlydisplaysoneovertravelalarm.
Duringmanualoperation,whenthetooltouchesanaxialtravelswitch,thetoolonlydeceleratesandstopsmotionon
currentaxis,andstillmoves
alongotheraxes.
Whenthetoolisinsafeposition,press[Reset]toclearthealarm.Pleaserefertothemanualofthemachinetoolfor
details.
Bothlimitalarmandsoftlimitalarmhaveadecelera tionstop,andthereforethesensingrangeofthelimitshouldhave
sufficientspace,
orelsethelimitprotectionwi llbedisabledduetoovertravel.
6. Alarmandself‐diagnosisfunction
Thesystemhassever allevels,andthealarmnumbersalsohavedifferenttype,asfollow:
0~1023: Gcodeprogramrunningalarminfo
1024~2048: Systemenvironmentalarminfo
6.1 NCprogramexecutionalarm
0000
:
Reset
0001
:
ProgNoEnd