BZ001M056A ADT‐DK300A/400A Engraving Machine
139
101
Zlockbrakeoutputport
101
4lockbrakeoutputport
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Configure brake signal output port; the default value is null. Brake
enable is set in axis configuration parameters. After brake function is
configured, if the corresponding axis has pulse signal
output, it will
outputbrakesignal,andturnoffbrakesignalifthereisnopulseoutput.
102 Spindlefrequencyalarmresetport
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Used for spindle inverter alarm clear port configuration; the default
valueisnull.
103 Cooleralarmdetectionport
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Usedforcooleralarminputportconfiguration;thedefaultvalueisnull.
104 Externalresetinputport
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========
Effectivetime : Instant
Note : Used for external reset button input port configuration; the default
valueisnull.
105 Elasticcutterinputport
Range : 0~23
Unit : None
Authority : Operationadminorhigher
Default : =========