BZ001M056A ADT‐DK300A/400A Engraving Machine
70
Parametertype S/N Description Effectivemode Defaultvalue Page
Generalparameter(P1.) 112 Xscrewoffsetfunctionenable Instant OFF
Generalparameter(P1.) 113 Yscrewoffsetfunctionenable Instant OFF
Generalparameter(P1.) 114 Zscrewoffsetfunctionenable Instant OFF
Generalparameter(P1.) 115 Ascrewoffsetfunctionenable Instant OFF
Generalparameter(P1.) 116 Xscrewoffsetpitch(mm) Instant 10.000
Generalparameter(P1.) 117 Yscrewoffsetpitch(mm) Instant 10.000
Generalparameter(P1.) 118 Zscrewoffsetpitch(mm) Instant 10.000
Generalparameter(P1.) 119 Ascrewoffsetpitch(mm) Instant 10.000
Generalparameter(P1.) 120 Xscrewoffsetstartposition(mm) Instant 0.000
Generalparameter(P1.) 121 Yscrewoffsetstartposition(mm) Instant 0.000
Generalparameter(P1.) 122 Zscrewoffsetstartposition(mm) Instant 0.000
Generalparameter(P1.) 123 Ascrewoffsetstartposition(mm) Instant 0.000
Generalparameter(P1.) 124 Xscrewoffsetendposition(mm) Instant 0.000
Generalparameter(P1.) 125 Yscrewoffsetendposition(mm) Instant 0.000
Generalparameter(P1.) 126 Zscrewoffsetendposition(mm) Instant 0.000
Generalparameter(P1.) 127 Ascrewoffsetendposition(mm) Instant 0.000
Generalparameter(P1.) 128 GotoM98time/lineenable Instant OFF
Generalparameter(P1.) 129 Systemstartreset Instant Notreset
Generalparameter(P1.) 130 Cooleralarmeffectivelevel Instant 0
Generalparameter(P1.) 131 Externalreseteffectivelevel Instant 0