ADTECH4 SeriesCNC Maintenance Manual
Range
:
OFF ON
Unit
:
None
Authority
:
Operation admin
Default
:
OFF
Effective time
:
Instant
Note
:
Enable and set this parameter to ON to jump to line N of X cycle of M98
instruction and start processing.
057
System home ON
Range
:
No, ask, auto
Unit
:
None
Authority
:
Operation admin
Default
:
No
Effective time
:
Instant
Note
:
Ask: when the system is restarted, it asks whether to execute home
operation; press the [EOB] button to execute.
Auto: when the system is restarted, it executes home operation
automatically.
058
Spindle brake delay (ms)
Range
:
0 ~ 60000
Unit
:
sec
Authority
:
Operation admin
Default
:
1000
Effective time
:
Instant
Note
:
Used to set the delay between actions of the principal axis brake switch
059
Rotation axis speed optimization feature (this parameter is invalid currently)
Range
:
Unit
:
Authority
:
Operation admin
Default
:
Effective time
:
Instant

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Adtech ADTECH4 CNC Series and is the answer not in the manual?

Adtech ADTECH4 CNC Series Specifications

General IconGeneral
BrandAdtech
ModelADTECH4 CNC Series
CategoryControl Systems
LanguageEnglish

Related product manuals