ADTECH4 SeriesCNC Maintenance Manual
function only can stop pulse in instant mode. Therefore, the instant stop
mode may cause mechanical vibration if the speed is too high. While
software scanning mode uses maximum acceleration mode and
decelerates according to the maximum acceleration set to every axis by
the user (parameter P2.029), and therefore overshot will occur.
018
X pulse command format (restart)
Y pulse command format (restart)
Z pulse command format (restart)
4 pulse command format (restart)
B pulse command format (restart)
C pulse command format (restart)
Range
:
0~1
Unit
:
None
Authority
:
Super admin
Default
:
1
Effective time
:
Restart
Note
:
Pulse command format setting is to configure the mode of output pulse.
The compatible command format of the motor drive should be known in
advance.
0 Pulse + pulse
1 Pulse + direction
019
X pulse logic direction (restart)
Y pulse logic direction (restart)
Z pulse logic direction (restart)
4 pulse logic direction (restart)
B pulse logic direction (restart)
C pulse logic direction (restart)
Range
:
0~1
Unit
:
None
Authority
:
Super admin
Default
:
1