Total Access 600R System Manual Section 4 User Interface Guide
61200600L1-1A © 2002 ADTRAN, Inc. 63
SYSTEM UTILITY > PING > % LOSS
Percentage loss based on ping returned from host (read-only).
SYSTEM UTILITY > TRACEROUTE
Utility program used to trace a data path to a final destination.
SYSTEM UTILITY > TRACEROUTE > TRACE TARGET
Specifies the IP address of the remote system to trace the routes to.
SYSTEM UTILITY > TRACEROUTE > MAXIMUM HOPS
Specifies the maximum number of router exchanges allowed when traveling to the final destination
(specified using the
TRACE TARGET field). Range is 1 to 30. Default is 30.
SYSTEM UTILITY > TRACEROUTE > TIMEOUT (IN SECS)
Specifies the maximum delay (in seconds) given to a host (along a path to the final destination) to respond
to the probe datagram sent before considering the packet a failure.
SYSTEM UTILITY > TRACEROUTE > RETRIES
Specifies the number of times the probe datagram is sent to each host (along the path to the final
destination).
SYSTEM UTILITY > TRACEROUTE > BEGIN TRACEROUTE
Activator to begin the traceroute process by sending a probe datagram with a Time To Live (TTL) value of
1.
SYSTEM UTILITY > RESET UNIT
Selecting this activator will power reset the unit.
SYSTEM UTILITY > TERMINAL MODE
The terminal mode gives the user a command-line prompt. From this prompt, you can:
Perform a reset with the command "reset"
Perform a factory restore with the command "factory_reset"
Configure the unit. The unit has the ability to download a text file which contains the configuration of
the entire unit. This configuration may then be altered in a text editor, and then uploaded to a unit. (See
DLP-013, Saving and Loading Text Configuration Using the Terminal Command Line, for further
assistance.)
Debug and troubleshoot. This function would be carried out with the assistance of ADTRAN Technical
Support.
Start and stop the fail-safe timer for the auto-config feature, (See DLP-014, Unit Installation Using The
Auto-Config Feature for details.)

Table of Contents

Other manuals for ADTRAN Total Access 600R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 600R and is the answer not in the manual?

ADTRAN Total Access 600R Specifications

General IconGeneral
BrandADTRAN
ModelTotal Access 600R
CategoryNetwork Router
LanguageEnglish

Related product manuals