SETTING ETHERNET IP PARAMETERS
Introduction
If the unit is connected to an IP network for Telnet, TFTP, or SNMP management, several IP parameters
must be set for the unit to communicate with the network. These parameters are described in this DLP
along with the procedures for setting them.
Prerequisite Procedures
This procedure assumes that the unit is connected to an IP network and is powered up.
Tools and Materials Required
• VT100 compatible terminal or computer with terminal emulation software
• Appropriate cable to connect terminal to the unit (customer-provided)
• DB-9 female to RJ-45 female adapter for connecting to the
CRAFT port on the rear of the unit. This
adapter is ADTRAN-proprietary and is provided with the unit.
• Ethernet cable from the
10/100BASET port on the unit to a hub (customer-provided)
• Use Ethernet crossover if going from the unit to a PC (customer-provided).
Please see your Network Administrator for the proper assignment of the following
parameters:
IP ADDRESS, SUBNET MASK, and DEFAULT GATEWAY.
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.