1. Connect the unit to your VT100 system (details found in DLP-001, Connecting the Terminal or PC to
the CRAFT Port).
2. Log in to the system with maximum rights (details for logging in are in DLP-002 and
DLP-003).
3. From the R
OUTER/CONFIG/INTERFACES (ETH[1]) menu, select the SETUP option and press <Enter>.
4. Select the P
RIMARY IP option and press <Enter>. Select IP ADDRESS and press <Enter>.
Enter the appropriate IP address.
5. From the ROUTER/CONFIG/INTERFACES (ETH[1])/SETUP/PRIMARY IP menu, select the SUBNET MASK
option and press <Enter>.
Enter the appropriate Subnet Mask.
6. From the ROUTER/CONFIG/ROUTES menu, select the DEFAULT GATEWAY option and press <Enter>.
Enter the appropriate Default Gateway.
7. Escape out to the ROUTER menu and log off by pressing <Ctrl + L>.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.
Perform Steps Below in the Order Listed

Table of Contents

Other manuals for ADTRAN Total Access 600R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ADTRAN Total Access 600R and is the answer not in the manual?

ADTRAN Total Access 600R Specifications

General IconGeneral
BrandADTRAN
ModelTotal Access 600R
CategoryNetwork Router
LanguageEnglish

Related product manuals