C. DryerMaster Controlling
• In DryerMaster Controlling mode the DryerMaster is controlling the process and runs until STOP DRYING is
activated, or a low level sensor is activated.
• The operator should regularly check the grain moisture graph for abnormalities.
• MOISTURE CALIBRATION for the lower moisture sensor should be done a least every 2-3 hours.
• When changing the TARGET MOISTURE a pop-up window will appear that will also show the Minimum and
Maximum alarm setpoints for the outlet grain.
Figure 121. DryerMaster controlling
D. Cooling
• The COOLING mode default timer setting is five minutes. See SETUP - TIMERS, to modify.
• Blowers continue to run and the burners turn OFF.
• When the timer runs out OR if the STOP COOLING button is activated, ALL blowers shut down immediately
and the RESTART DRYER button appears.
4. OPERATION CONTINUOUS MIXED-FLOW GRAIN DRYER WITH COMMANDER CONTROL SYSTEM