C. DryerMaster Controlling
In DryerMaster Controlling mode the DryerMaster is controlling the process and runs until STOP DRYING is
activated, or a low level sensor is activated.
The operator should regularly check the grain moisture graph for abnormalities.
MOISTURE CALIBRATION for the lower moisture sensor should be done a least every 2-3 hours.
When changing the TARGET MOISTURE a pop-up window will appear that will also show the Minimum and
Maximum alarm setpoints for the outlet grain.
Figure 121. DryerMaster controlling
D. Cooling
The COOLING mode default timer setting is five minutes. See SETUP - TIMERS, to modify.
Blowers continue to run and the burners turn OFF.
When the timer runs out OR if the STOP COOLING button is activated, ALL blowers shut down immediately
and the RESTART DRYER button appears.
4. OPERATION CONTINUOUS MIXED-FLOW GRAIN DRYER WITH COMMANDER CONTROL SYSTEM