line voltage and frequency, 15
linear range, 16
linearity measurements, 17
link configuration selection, 39
M
MAC
address, 32
location of label, 25
maintenance
introduction, 111
overview, 118
parts, 153
manual configuration
of LAN, 46
of LAN with handheld controller, 51
N
nano flow cells
dimensions, 92
parts, 162
negative absorbance, 101
noise and drift (ASTM), 16
O
operating altitude, 15
operation temperature, 15
optimization
choosing a flow cell, 90
detector performance, 88
for sensitivity, selectivity, linearity,
dispersion, 91
how to get the best performance, 88
margins for negative absorbance, 101
of selectivity, 102
of the system, 62
overview, 89
peak width, 93
sample and reference wavelength, 94
slit width, 97
spectra acquisition, 100
P
parts identification
accessory kit, 166
for maintenance, 153
high pressure (micro) flow cell, 160
main assemblies for maintenance, 155
nano flow cells, 162
overview for maintenance, 154
semi-micro flow cell, 158
standard flow cell, 156
PC and Agilent ChemStation Setup, 54
peak width (response time), 93
performance
optimization, 88
specifications, 16
photometric accuracy, 92
physical specifications, 15
humidity, 15
line voltage and frequency, 15
operating altitude, 15
operation temperature, 15
power consumption, 15
safety standards, 15
weight and dimensions, 15
power
considerations, 12
consumption, 15
cords, 12
product CD, 20
programmable slit width, 16
R
rear view of module, 25
recalibration of wavelength, 108, 193
recyclable material, 17
reference conditions (ASTM), 17
repair
introduction, 111
repairs
cleaning the instrument, 114
correction leaks, 147
definition of, 112
exchanging a flow cell, 121
exchanging a lamp, 119
exchanging holmium oxide filter, 144
introduction, 112
of the detector, 117
replacing CompactFlash card, 149
replacing firmware, 150
replacing leak handling system, 148
replacing semi-micro flow cell
capillaries, 136
replacing STD flow cell capillaries, 131
the high pressure flow cell, 129
the standard/semi-micro flow cell, 124
using the ESD strap, 115
warnings and cautions, 112
response time (peak width), 93
run recovery, 76
automatic, 77
manual, 78
settings, 76
S
safety information
standards, 15
sample and reference wavelength, 94
sample, holmium and dark current
spectrum, 193
selectivity optimization, 102
semi-micro flow cell
dimensions, 92
parts, 158
serial number
entered on control module, 190
service manual, 20
site requirements, 12
slit width, 16, 97
specifications
analog signal output, 17
communications, 17
control and data evaluation, 16
diode width, 16
flow cell, 16
GLP features, 17
linear range, 16
noise and drift (ASTM), 16
performance, 16
physical, 15
programmable slit width, 16
safety and maintenance, 17
wavelength accuracy, 16
wavelength bunching, 16
wavelength range, 16
spectra
acquisition, 100
settings, 81
stack configuration, 22, 23

Table of Contents

Other manuals for Agilent Technologies 1100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 1100 Series and is the answer not in the manual?

Agilent Technologies 1100 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model1100 Series
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals