Agilent 6890 Gas Chromatograph Service Manual
Adjust failure, 850-21
Bad cksum,850-20
Bad fact cal,850-20
Calib deleted, 830-6
Config changed, 830-3
Electrometer,850-4
Invalid pid,850-19
Invalid type, 850-17
I/O failure, 850-21
Makeup gas,820-3
Module rev,850-15
Temp sensor, 850-10
Temp too hot, 850-9
Type mismatch,850-18
Wrong module, 850-16
F inlet
Bad cksum
,850-20
Bad fact cal,850-20
Calib deleted, 830-5
Config changed, 830-4
Flow cal fail,830-8
Invalid pid,850-19
Invalid type, 850-18
I/O failure, 850-21
Module rev,850-16
Temp sensor, 850-11
Temp too hot, 850-10
Wrong module, 850-17
F TCD filament open,850-5
F TCD filament short,850-6
Fan
Injection port cover, removal
,410-16
Injection port, removal, 410-16
Motor replacement, 420-15
Pnematics area, removal, 410-18
Replacement,420-14
Fast heating oven,510-5
Fatal errors,860-1
Fault 200Pneumatics shutdown: faulty board,
850-1
Fault 201Pneumatics shutdown: faulty board,
850-1
Fault 203Signal DSP faulty, 850-2
Fault 204Sig DSP ROM broken,850-2
Fault 205Sig DSP RAM broken, 850-3
Fault 206Sig DSP registers,850-3
Fault 207Sig DSP data corrupt,850-3
Fault 208Signal path test failed,850-4
Fault 209Signal path test failed,850-4
Fault 210Signal path test failed,850-4
Fault 211Signal path test failed,850-4
Fault 212Front electrometer out of
specification
, 850-4
Fault 213Back electrometer out of
specification
, 850-4
Fault 214Front detector flame out,850-5
Fault 215Back detector flame out,850-5
Fault 216Front TCD filament open,850-5
Fault 217Back TCD filament open, 850-5
Fault 218Front TCD filament shorted,850-6
Fault 219Back TCD filament shorted,850-6
Fault 220Heater over current, 850-6, 850-8
Fault 222Oven thermal shutdown, 850-8
Fault 223Oven thermal shutdown, 850-9
Fault 224Oven thermal shutdown, 850-9
Fault 225Front detector thermal shutdown,
850-9
Fault 226Front detector thermal shutdown,
850-10
Fault 227Back detector thermal shutdown,
850-10
Fault 228Back detector thermal shutdown,
850-10
Fault 229Front inlet thermal shutdown, 850-10
Fault 230Front inlet thermal shutdown, 850-11
Fault 231Back inlet thermal shutdown, 850-11
Fault 232Back inlet thermal shutdown, 850-12
Fault 233Aux 1 thermal shutdown, 850-12
Fault 234Aux 1 thermal shutdown, 850-12
Fault 235Aux 2 thermal shutdown, 850-13
Fault 236Aux 2 thermal shutdown, 850-13
Fault 237No line interrupt thermal
shutdown
, 850-13
Fault 238Faulty line interrupt thermal
shutdown
, 850-14
Fault 239Mux ADC thermal shutdown, 850-14
Fault 240Mux ADC offset value, 850-14
Fault 241Line sense reading thermal
shutdown
, 850-14

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 6890 Plus and is the answer not in the manual?

Agilent Technologies 6890 Plus Specifications

General IconGeneral
BrandAgilent Technologies
Model6890 Plus
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals