Agilent Technologies
Agilent 6500 Series
Q-TOF LC/MS system
Maintenance Guide
Research Use Only. Not for use in Diagnostic
Procedures.

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 6500 Series and is the answer not in the manual?

Agilent Technologies 6500 Series Specifications

General IconGeneral
TypeQ-TOF LC/MS
Dynamic Range5 orders of magnitude
Ion SourceElectrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI)
Scan SpeedUp to 20, 000 amu/second
Dimensions74 cm (W)
Resolution> 40, 000 FWHM

Summary

Agilent 6500 Series Q-TOF LC/MS System Operation

Starting and Shutting Down the LC/MS System

Procedures for starting up and shutting down the Q-TOF LC/MS instrument.

Changing Ion Sources on the LC/MS

Steps for removing and installing different ion sources for the LC/MS system.

Agilent 6500 Series Q-TOF LC/MS Maintenance

Calibrant Delivery System and Divert Valve Maintenance

Maintenance tasks related to the calibrant delivery system and divert valve.

Electrospray Ion Source Maintenance

Procedures for removal, cleaning, and reassembly of the electrospray ion source.

ESI with Agilent Jet Stream Technology Maintenance

Maintenance for the electrospray interface with Agilent Jet Stream Technology.

APCI Source Maintenance

Procedures for opening, closing, and maintaining the APCI source.

Multimode Source and HPLC-Chip/MS Interface

Cleaning and adjusting the multimode source and maintaining the HPLC-Chip/MS interface.

Ion Transfer Capillary Maintenance

Steps to remove, clean, and reinstall the ion transfer capillary.

Manifold and Ion Optics Cleaning

Procedures for opening, closing, and cleaning the manifold and ion optics.

High Pressure Ion Funnel (6550) Cleaning

Cleaning the high pressure ion funnel for the 6550 Q-TOF system.

Vacuum System Maintenance

Procedures to maintain the instrument's vacuum system.

Agilent 6500 Series Q-TOF LC/MS Reference Information

General Safety Precautions

Safety warnings and precautions for operating the LC/MS system.

Environmental Operating Conditions

Specifications for environmental conditions for instrument operation.

Replaceable Fuses and Specifications

Information on fuses used in the instrument and their replacement.

Related product manuals