Event and Accounting Logs
7450 ESS System Mangement Guide Page 495
The to command cannot be modified or re-entered. If the destination or maximum size of an SNMP
or memory log needs to be modified, the log ID must be removed and then re-created.
Default none
Parameters size — The size parameter defines the number of events stored in this memory log.
Default 100
Values 50 — 1024
to syslog
Syntax to syslog syslog-id
Context config>log>log-id
Description This is one of the commands used to specify the log ID destination. This parameter is mandatory
when configuring a log destination.
This command instructs the alarms and traps to be directed to a specified syslog. To remain consistent
with the standards governing syslog, messages to syslog are truncated to 1k bytes.
The source of the data stream must be specified in the from command prior to configuring the
destination with the to command.
The to command cannot be modified or re-entered. If the destination or maximum size of an SNMP
or memory log needs to be modified, the log ID must be removed and then re-created.
Default none
Parameters syslog-id — Instructs the events selected for the log ID to be directed to the syslog-id. The character-
istics of the syslog-id referenced here must have been defined in the config>log>syslog syslog-id
context.
Values 1 — 10
time-format
Syntax time-format {local | utc}
Context config>log>log-id
Description This command specifies whether the time should be displayed in local or Coordinated Universal Time
(UTC) format.
Default utc
Parameters local — Specifies that timestamps are written in the system’s local time.
utc — Specifies that timestamps are written using the UTC value. This was formerly called
Greenwich Mean Time (GMT) and Zulu time.