System Management
Basic System Configuration Guide 495
Falling Event Id : 0 Threshold : 0
Sample Interval : 3 SampleType : absolute
Startup Alarm : either Owner : TiMOS CLI
Variable: tmnxCpmFlashPercentageUsed.1.10.2
Alarm Id : 4 Last Value : 0
Rising Event Id : 5 Threshold : 40
Falling Event Id : 6 Threshold : 50
Sample Interval : 4 SampleType : absolute
Startup Alarm : either Owner : TiMOS CLI
=================================================================
=================================================================
Threshold Events
=================================================================
Description: TiMOS CLI - cflash capacity alarm rising event
using percentages
Event Id : 1 Last Sent : 07/23/2015 18:15:46
Action Type : both Owner : TiMOS CLI
Description: TiMOS CLI - cflash capacity warning rising event
Event Id : 2 Last Sent : never
Action Type : both Owner : TiMOS CLI
Description: TiMOS CLI - cflash capacity warning falling event
Event Id : 3 Last Sent : 07/23/2015 18:15:46
Action Type : both Owner : TiMOS CLI
Description: TiMOS CLI - cflash capacity warning rising event
using percentages
Event Id : 4 Last Sent : never
Action Type : both Owner : TiMOS CLI
Description: TiMOS CLI - cflash capacity alarm rising event
using percentages
Event Id : 5 Last Sent : never
Action Type : both Owner : TiMOS CLI
Description: TiMOS CLI - cflash capacity alarm falling event
using percentages
Event Id : 6 Last Sent : 07/23/2015 18:15:46
Action Type : both Owner : TiMOS CLI
=================================================================
=================================================================
Threshold Events Log
=================================================================
Description : TiMOS CLI - cflash capacity alarm rising
event using percentages : value=3192120,
>=10 : alarm-index 1, event-index 1 alarm-
variable OID tmnxCpmFlashUsed.1.10.1
Event Id : 1 Time Sent : 07/23/2015 18:15:46
Description : TiMOS CLI - cflash capacity warning falling
event : value=0, <=30 : alarm-index 2, event-
index 3 alarm-variable OID tmnxCpmFlashUsed.
1.10.2
Event Id : 3 Time Sent : 07/23/2015 18:15:46