Rockwell Automation Publication 1441-UM001B-EN-P - September 2012 151
Collecting and Reviewing Data Chapter 5
The Offroute measurement screen appears.
4. Select the a pre-defined measurement icon to store an Offroute
measurement at the current point.
5. Connect the a transducer and press Enter to start the measurement.
The measurement screen appears.
6. For manual entry points, enter the magnitude value with the numeric key
pad.
7. If desired, press F3 (Notes) to assign inspection codes to each point.
The Dynamix 2500 data collector unloads inspection codes when you
unload the unscheduled data to Emonitor.
See Select Inspection Codes on page 137
.
8. After the data collector collects the measurement, press Enter to accept the
measurement.
The green status indicator illuminates when the measurement is complete
and the Offroute screen appears. The measurement is stored as an Offroute
measurement at the current point.
9. Press F4 (Esc) to return to the Data Collection screen.